Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Sens ; 8(4): 1639-1647, 2023 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-36967522

RESUMO

Microneedle lactate sensors may be used to continuously measure lactate concentration in the interstitial fluid in a minimally invasive and pain-free manner. First- and second-generation enzymatic sensors produce a redox-active product that is electrochemically sensed at the electrode surface. Direct electron transfer enzymes produce electrons directly as the product of enzymatic action; in this study, a direct electron transfer enzyme specific to lactate has been immobilized onto a microneedle surface to create lactate-sensing devices that function at low applied voltages (0.2 V). These devices have been validated in a small study of human volunteers; lactate concentrations were raised and lowered through physical exercise and subsequent rest. Lactazyme microneedle devices show good agreement with concurrently obtained and analyzed serum lactate levels.


Assuntos
Elétrons , Ácido Láctico , Humanos , Eletrodos , Transporte de Elétrons , Sujeitos da Pesquisa
2.
ACS Sens ; 4(4): 1072-1080, 2019 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-30950598

RESUMO

Antimicrobial resistance poses a global threat to patient health. Improving the use and effectiveness of antimicrobials is critical in addressing this issue. This includes optimizing the dose of antibiotic delivered to each individual. New sensing approaches that track antimicrobial concentration for each patient in real time could allow individualized drug dosing. This work presents a potentiometric microneedle-based biosensor to detect levels of ß-lactam antibiotics in vivo in a healthy human volunteer. The biosensor is coated with a pH-sensitive iridium oxide layer, which detects changes in local pH as a result of ß-lactam hydrolysis by ß-lactamase immobilized on the electrode surface. Development and optimization of the biosensor coatings are presented, giving a limit of detection of 6.8 µM in 10 mM PBS solution. Biosensors were found to be stable for up to 2 weeks at -20 °C and to withstand sterilization. Sensitivity was retained after application for 6 h in vivo. Proof-of-concept results are presented showing that penicillin concentrations measured using the microneedle-based biosensor track those measured using both discrete blood and microdialysis sampling in vivo. These preliminary results show the potential of this microneedle-based biosensor to provide a minimally invasive means to measure real-time ß-lactam concentrations in vivo, representing an important first step toward a closed-loop therapeutic drug monitoring system.


Assuntos
Antibacterianos/análise , Técnicas Biossensoriais/métodos , Monitoramento de Medicamentos/métodos , Agulhas , Penicilina G/análise , Penicilina V/análise , Antibacterianos/química , Técnicas Biossensoriais/instrumentação , Monitoramento de Medicamentos/instrumentação , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Hidrólise , Irídio/química , Limite de Detecção , Penicilina G/química , Penicilina V/química , Estudo de Prova de Conceito , beta-Lactamases/química
3.
Lancet Digit Health ; 1(7): e335-e343, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-33323208

RESUMO

BACKGROUND: Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-based ß-lactam biosensor in healthy volunteers. METHODS: This first-in-human, proof-of-concept study was done at the National Institute of Health Research/Wellcome Trust Imperial Clinical Research Facility (Imperial College London, London, UK). The study was approved by London-Harrow Regional Ethics Committee. Volunteers were identified through emails sent to a healthy volunteer database from the Imperial College Clinical Research Facility. Volunteers, who had to be older than 18 years, were excluded if they had evidence of active infection, allergies to penicillin, were at high risk of skin infection, or presented with anaemia during screening. Participants wore a solid microneedle ß-lactam biosensor for up to 6 h while being dosed at steady state with oral phenoxymethylpenicillin (five 500 mg doses every 6 h). On arrival at the study centre, two microneedle sensors were applied to the participant's forearm. Blood samples (via cannula, at -30, 0, 10, 20, 30, 45, 60, 90, 120, 150, 180, 210, 240 min) and extracellular fluid (ECF; via microdialysis, every 15 min) pharmacokinetic (PK) samples were taken during one dosing interval. Phenoxymethylpenicillin concentration data obtained from the microneedles were calibrated using locally estimated scatter plot smoothing and compared with free-blood and microdialysis (gold standard) data. Phenoxymethylpenicillin PK for each method was evaluated using non-compartmental analysis. Area under the concentration-time curve (AUC), maximum concentration, and time to maximum concentration were compared. Bias and limits of agreement were investigated with Bland-Altman plots. Microneedle biosensor limits of detection were estimated. The study was registered with ClinicalTrials.gov, number NCT03847610. FINDINGS: Ten healthy volunteers participated in the study. Mean age was 42 years (SD 14). Seven (70%) were men. Microdialysis and microneedle results were similar for phenoxymethylpenicillin ECF maximum concentration (0·74 mg/L vs 0·64 mg/L; 95% CI -0·24 to 0·44; p=0·53), time to maximum concentration (1·18 h vs 1·10 h; -0·52 to 0·67; p=0·79), and AUC (1·54 mg × h/L vs 1·67 mg × h/L; -1·10 to 0·85; p=0·79). In total, 440 time points were compared with mean difference between measurements -0·16 mg/L (95% CI -1·30 to 0·82). Mean phenoxymethylpenicillin AUCs for free serum and microneedle PK were similar (1·77 mg × h/L [SD 0·59] vs 1·67 mg × h/L [1·00]; -0·77 to 0·97; p=0·81). Median coefficient of variation between sensors within individuals was 7% (IQR 4-17). Limit of detection for the microneedles was estimated at 0·17 mg/L. INTERPRETATION: This study is proof-of-concept of real-time, microneedle sensing of penicillin in vivo. Future work will explore microneedle use in patient populations, their role in data generation to inform dosing recommendations, and their incorporation into closed-loop control systems for automated drug delivery. FUNDING: National Institute for Health Research Imperial Biomedical Research Centre, Mérieux Foundation.


Assuntos
Antibacterianos , Técnicas Biossensoriais , Monitoramento de Medicamentos , Voluntários Saudáveis , Agulhas , Penicilina V , Adulto , Antibacterianos/administração & dosagem , Antibacterianos/farmacocinética , Líquido Extracelular , Feminino , Humanos , Londres , Masculino , Microdiálise , Penicilina V/administração & dosagem , Penicilina V/farmacocinética
4.
J Am Chem Soc ; 139(32): 11073-11080, 2017 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-28598611

RESUMO

The presence of energetically low-lying triplet states is a hallmark of organic semiconductors. Even though they present a wealth of interesting photophysical properties, these optically dark states significantly limit optoelectronic device performance. Recent advances in emissive charge-transfer molecules have pioneered routes to reduce the energy gap between triplets and "bright" singlets, allowing thermal population exchange between them and eliminating a significant loss channel in devices. In conjugated polymers, this gap has proved resistant to modification. Here, we introduce a general approach to reduce the singlet-triplet energy gap in fully conjugated polymers, using a donor-orthogonal acceptor motif to spatially separate electron and hole wave functions. This new generation of conjugated polymers allows for a greatly reduced exchange energy, enhancing triplet formation and enabling thermally activated delayed fluorescence. We find that the mechanisms of both processes are driven by excited-state mixing between π-π*and charge-transfer states, affording new insight into reverse intersystem crossing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...